For projects with limited wall header space and overhead access.
Ceiling Mounted Air Curtain Series
Ceiling Mounted Air Curtain
Ceiling mounted air curtain for constrained headers, recessed ceiling plans, and projects where the air curtain should stay visually integrated with the ceiling while door width, mounting height, and service access are checked.
- Recessed ceiling openings
- Overhead mounting
- Limited wall space

Technical parameters
Ceiling Mounted Air Curtain technical parameters
Check the core technical values immediately after the product view, then continue into application fit, construction notes, and product documents.
| Spec field | Selection value | Use boundary |
|---|---|---|
| Model number | Ceiling Series | Model identifier |
| Airflow | air volume 1260-3300 m3/h high speed; 1000-2600 m3/h low speed by model | Project input |
| Voltage and phase | Confirm the US voltage option | Confirm by model |
| Power input | 260-670 W high speed; 234-603 W low speed by model; confirm voltage and exact model power | Confirm by model |
| Sound rating | 50-60 dB high speed; 45-54 dB low speed by model; installed sound depends on ceiling conditions | Project input |
| Dimensions | 900/1000/1200/1500/1800/2000 x 225 x 290 mm model sizes; confirm inch dimensions | Confirm by model |
| Weight | Confirm shipping and installed weight | Confirm by model |
| Mounting type | Ceiling mounted / recessed; mounting height 3.5-4.0 m or 4.0-5.0 m by model class | Project input |
| Warranty | Confirm warranty terms by product and sales channel | Confirm by model |
Documentation
Certification status
| Reference | Status | Note |
|---|---|---|
| US certification documents | Contact for documents | Confirm model documents before submittal use or project approval. |
Model table
Ceiling Mounted Air Curtain Source Parameters
| Source parameter | Published source value | Selection use |
|---|---|---|
| Air volume | 1260-3300 m3/h high speed; 1000-2600 m3/h low speed by model | Use as a source airflow range; confirm exact model data before submittal use |
| Air velocity | 17 / 14 m/s or 21 / 18 m/s high / low by model class | Use as a source velocity range; confirm selected class before submittal use |
| Motor power | 260-670 W high speed; 234-603 W low speed by model | Confirm voltage and exact model power before quotation |
| Noise level | 50-60 dB high speed; 45-54 dB low speed by model | Use as a source sound range; installed sound depends on ceiling and duct conditions |
| Unit size | 900-2000 x 225 x 290 mm by model | Match length to finished door width and verify plenum clearance |
| Mounting height | 3.5-4.0 m or 4.0-5.0 m by model class | Check ceiling opening, access panel, and discharge path before layout use |
Product overview
Ceiling Mounted Air Curtain
Installation inputs should include finished opening width, clear height, ceiling cassette length, plenum depth, access panel, voltage, controls, and doorway photos.
Use a ceiling mounted air curtain when the doorway needs recessed overhead integration; compare surface-mounted air curtain series when the ceiling cannot provide plenum depth, service access, or a clean discharge path.
Ceiling air curtain model documents should be requested with finished opening width, mounting height, ceiling opening size, plenum depth, voltage, controls, and project photos.
Model notes
What the equipment views help check
Photos support form factor, installation, control, and service checks before the project moves into model documents.
Confirm ceiling access, intake clearance, and service space before review.
Panel fit, access, and finish should be checked against the ceiling plan.
Product detail
Construction and Selection Notes
Ceiling-mounted form factor for limited wall-header space
Use finished door width, mounting height, ceiling opening, and service panel access before comparing air curtain sizes
Discreet installation path for modern lobbies, recessed entries, or cold-room-adjacent doors
Supplied model table lists 900 / 1000 / 1200 / 1500 / 1800 / 2000 mm lengths, 3.5-5.0 m mounting-height classes, and 1260-3300 m3/h high-speed air volume by model
Moisture-resistant details should be verified by current model documents
Service access and ceiling panel fit should be reviewed before layout release